(13.58.5.57)
Users online: 11260     
Ijournet
Email id
 

Bulletin of Pure & Applied Sciences- Mathematics and Statistics
Year : 2017, Volume : 36e, Issue : 2
First page : ( 306) Last page : ( 310)
Print ISSN : 0970-6577. Online ISSN : 2320-3226.
Article DOI : 10.5958/2320-3226.2017.00032.7

Evaluation of the availability and M.T.T.F. of two unit standby redundant complex systems

Tyagi Vivek1, Sharma Viresh2,*, Tyagi Ajay3

1Deptt. of Statistics, N.A.S. (P.G.) College, Meerut, Uttar Pradesh, 250003. E-mail: avikrishna94@yahoo.co.in

2Deptt. of Mathematics, N.A.S. (P.G.) College, Meerut, Uttar Pradesh, 250003. E-mail: vireshsharma1@yahoo.com

3Research Scholar, Mewar University, Gangrar, Chittorgarh, Rajasthan, 312901. E-mail: ajaytyagi2009@gmail.com

*Corresponding Author: Viresh Sharma, Deptt. of Mathematics, N.A.S. (P.G.) College, Meerut, Uttar Pradesh, 250003. E-mail: vireshsharma1@yahoo.com

Online published on 16 January, 2018.

Abstract

The authors have considered a complex system composed of two units in parallel redundancy which has been studied to evaluate M.T.T.F. and availability. Supplementary variable technique has been utilised to derive various state probabilities and the operational availability. The repair facility is available in either one unit or the whole system fails. After failure of one unit, the system is undertaken for repair, of course, the other unit is in operative mode. If during the repair of the first unit, the second unit also fails then the system is assumed to go to down state.

Top

Keywords

M.T.T.F, Supplementary variable, Repairable system, Redundancy, Availability.