(18.225.149.238)
Users online: 10849     
Ijournet
Email id
 

Asian Journal of Pharmaceutical Analysis
Year : 2022, Volume : 12, Issue : 4
First page : ( 253) Last page : ( 257)
Print ISSN : 2231-5667. Online ISSN : 2231-5675.
Article DOI : 10.52711/2231-5675.2022.00041

Development and validation of RP-HPLC method for simultaneous estimation of haloperidol and trihexyphenidyl hydrochloride in tablet dosage form

Patel Kalpesh N1,*, Gajjar Umang H2, Patel Paresh U2, Pancholi Shyam Sunder1

1Department of Pharmaceutical Chemistry and Quality Assurance, Ganpat University - Shree S. K. Patel College of Pharmaceutical Education and Research, Kherva, Mehsana, Gujarat, India - 384012

2Department of Pharmacognosy, Ganpat University - Shree S. K. Patel College of Pharmaceutical Education and Research, Kherva, Mehsana, Gujarat, India - 384012

*Corresponding Author E-mail: knp04@ganpatuniversity.ac.in

Online published on 4 March, 2023.

Abstract

Haloperidol is a common antipsychotic drug used to treat schizophrenia, and Trihexyphenidyl hydrochloride is an antiparkinsonian medication. The combination formulation is used to treat schizophrenia as well as depression. A simple, accurate, and precise assay as well as a rapid stability-indicating reversed-phase high performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of Haloperidol (HAL) and Trihexyphenidyl hydrochloride (THP) from their combination drug product have been developed and validated. The proposed method is based on reversed-phase separation of the two drugs using a Zorbax Eclipse XDB C18 column (150 mm × 4.6 mm, 5 um) kept at 30°C. The optimal mobile phase was composed of 0.5 mL triethylamine 0.05 M phosphate buffer having pH 3.75: acetonitrile: (65:35 v/v), a flow rate of 1.2 mL.min-1, and PDA detection at 210 nm. The method was validated in accordance with ICH standards. It was found to be precise and reproducible. Linearity was achieved in the concentration ranges of 6-60 ug mL-1 for HAL and 8-80 ug mL-1 for THP, with correlation coefficients of 0.999 and 1.000, respectively. The mean percent recovery of triplicate samples at each level for both drugs was 99.10-100.7% for Haloperidol and 98.7-100.6% for Trihexyphenidyl hydrochloride. The proposed method can be used to successfully test quality control and stability samples from bulk manufacturing and pharmaceutical dosage forms.

Top

Keywords

Haloperidol, Trihexyphenidyl hydrochloride, Schizophrenia, Acetonitrile, PDA detection.

Top

  
║ Site map ║ Privacy Policy ║ Copyright ║ Terms & Conditions ║ Page Rank Tool
809,438,179 visitor(s) since 30th May, 2005.
All rights reserved. Site designed and maintained by DIVA ENTERPRISES PVT. LTD..
Note: Please use Internet Explorer (6.0 or above). Some functionalities may not work in other browsers.